elector S10

elector S10

Corrosion-protection device for heating systems up to 1.5 m3 system volume

The corrosion-protection device elector S10 is suitable for use in central heating systems or similar closed water systems with a water volume up to 1.5 m3.

By combination of proven technologies in one appliance the elector S10 is an ideal safety device of central heating systems for water side corrosion without the addition of chemical corrosion inhibitors.

Main function of the elector S10 is the electrochemical water-treatment, which results in an increase of the pH-value, in a constant oxygen consumption and in a clarification of the system water. A cyclonic water flow and separation plates installed inside of the elector enhance the separation of impurities and the venting of the heating system by an air-vent. In addition, a strong magnetic filter rod of rare-earth provides the effective removal of magnetic particles from the heating water.

In conclusion the usage of an elector S10 means:

  • Separation of circulating impurities from the system water by a cyclone effect and separation plates
  • Separation of magnetic particles by a strong magnetic filter rod
  • Clean and clear system water
  • Reduced conductivity of the heating water
  • Stable pH >8.3
  • Constant oxygen consumption und deaeration, resulting in an decrease of the oxygen content in the entire system
  • Protection of the metals in the system by a water quality which supports the formation of natural protective layers and passivation (corrosion protection)

The electrochemical water treatment is a well known method for an eco-logical corrosion protection in central heating systems and is a recommended method for refurbishment and protection of central heating systems in case of water containing oxygen resulting in corrosion. (see Swiss guidline SWKI). The increase of the pH-value by electrochemically formed hydroxide is state of the art technology and a safe way to operate a central heating in combination with demineralised water in a low-salt operation style according to VDI 2035.

The elector heating water conditioner offer a proven corrosion protection for maintaining the central heating and are an ideal safety device especially for older heating systems after flushing, for example with the cleaning and dispersing agent OXILIN-P20 for protection from the formation of new sludge.

Installation in bypass or full-flow

Depending on the application, we recommend the installation of the S10 in a bypass or full flow (flow or return) of the central heating.

In older systems, where the main focus is the oxygen consumption and the system refurbishment, the elector should be installed in a bypass. For this purpose the elector is available as elector S10-B, which is supplied with the connection set for bypass installation.

In younger systems or in situations where the main focus is on stabilising the pH-value, the elector S10 can be installed in full flow. For this purpose the elector is available as elector S10-V.

Product Features

The 360° connection concept allows an easy integration into the main flow or main return in horizontal or vertical connection.
The 360° connection concept allows an easy integration into the main flow or main return in horizontal or vertical connection.
Even in bypass installation the 360° connection concept shows its flexibility.
Even in bypass installation the 360° connection concept shows its flexibility.
A powerful magnetic filter rod with special polarity and a holding force fo 26 kgs is placed where the magnetite should be separated - right in the flow.
A powerful magnetic filter rod with special polarity and a holding force fo 26 kgs is placed where the magnetite should be separated - right in the flow.
A cyclone type water flows enhances the deposition of suspended solids and supports the deareation.
A cyclone type water flows enhances the deposition of suspended solids and supports the deareation.
The high-purity elector magnesium electrode provides as part of the galvanic cell the function of the electrochemical water treatment.
The high-purity elector magnesium electrode provides as part of the galvanic cell the function of the electrochemical water treatment.
A specially designed separation plated serves as enhancement of the separation by causing turbulences.
A specially designed separation plated serves as enhancement of the separation by causing turbulences.

Technical Data

Application area:Electrochemical Heating Water Conditioning for corrosion protection in heating systems
Working temperature:max. 90°C
Operational pressure:3 bar
Test pressure:6 bar
Vessel material:Stainless steel 1.4301 (V2A)
Insulation:Caruso-Iso-Bond
hardly inflammable, meets the B1 requirements according DIN 4102 - Part 1, toxicological harmless in accordance to Oeko-Tex Standard 100, UV-resistant and safe from decomposing, 100% recyclable and environmentally friendly, safe from mold infestation according to DIN IEC 68, allergy friendly
Shipment:

- elector S10 corrosion-protection device
- Connecting kit

Installation instruction:

The elector S10-V is for full flow installation (flow or return).

The device S10-B is for installation in a bypass. In some situations an additional feeding pump is necessary. The discharge flow through must be throttled to 2 liters per minute. If a pump is necessary we rocommend a 1" feeding pump (eg. Wilo Stratos PICO 25/1-4 difference pressure constant).


elector modelSystem volume
(without buffer storage)
Heating output
estimated*
Assembly~max. flow rate m3/hΔp bei ~max. Durchfluss [kPa]Article no.
elector S10-V1,5 m3

~18,5 l/kW UFH

~12 l/kW radiators

Wall - Full flow4.35.4414020
elector S10-BWall - bypass0.12--14040

 *Please add approx. 20% to the heating power in case of old heating systems with new heater

 

elector S10 dimensions

Dimensions in mm
ADiameter233
BDinstance container - Wall80
CTotal height655
DHeight container465
ECentre bracket - centre inlet horizontal115
FCentre bracket - centre outlet horizontal51
GCentre container - centre inlet / outlet vertical60
HDistance (recommended)250
Inlet bottom, Outlet top11/4"

 

 

Text for invitation to tender - bypass installation

Corrosion-protection device elector S10-B

Electrochemical water treatment for
corrosion protection in central heating
systems. Function without external
energy or chemical additives for
the constant consumption of
oxygen, increase of the pH-value
to an alcaline level according to
VDI 2035, cleaning and purification
of the system water, prevention
and removal of sludge,
corrosion protection by formation
of natural layers in the system.

Container made from stainless-steel
with integrated magnesium electrode
and function control instrument,
separation plates for removal of
suspended solids, neodym magnetic
filter rod for removal of magnetic
particles.

Operating pressure max. 3 bar
Temperature max. 90°C
For heating systems with ≤1.5 m³ volume
(without buffer storage)

Insulation Caruso-Iso-Bond,
hardly inflammable, meets the B1
requirements according DIN 4102 -
Part 1, toxicological harmless in
accordance to Oeko-Tex Standard 100,
UV-resistant and safe from
decomposing, 100% recyclable and
environmentally friendly, safe from
mold infestation according to DIN
IEC 68, allergy friendly
automatic air-vent, Valve for
elutriation and draining,
access eye and cleaning port,
incl. connecting kit with water
meter for discharge control.

Installation in bypass of the heating
system to ensure constant discharge
of a part from the heating water.
Wall assembly.

A 1" feeding pump, eg. UPS 25-40 or
Wilo RS 25/4, is required to grant the
steady discharge flow through the
elector. This pump should be
synchronised with the circulation pump.
The pump is not included.

Manufacturer: elector GmbH, Germany
Model: elector S10-B
Article-no.: 14040

Text for invitation to tender - full-flow installation

Corrosion-protection device elector S10-V

Electrochemical water treatment for
corrosion protection in central heating
systems. Function without external
energy or chemical additives for
the constant consumption of
oxygen, increase of the pH-value
to an alcaline level according to
VDI 2035, cleaning and purification
of the system water, prevention
and removal of sludge,
corrosion protection by formation
of natural layers in the system.

Container made from stainless-steel
with integrated magnesium electrode
and function control instrument,
separation plates for removal of
suspended solids, neodym magnetic
filter rod for removal of magnetic
particles.

Operating pressure max. 3 bar
Temperature max. 90°C
For heating systems with ≤1.5 m³ volume
(without buffer storage)

Insulation Caruso-Iso-Bond,
hardly inflammable, meets the B1
requirements according DIN 4102 -
Part 1, toxicological harmless in
accordance to Oeko-Tex Standard 100,
UV-resistant and safe from
decomposing, 100% recyclable and
environmentally friendly, safe from
mold infestation according to DIN
IEC 68, allergy friendly
automatic air-vent, Valve for
elutriation and draining,
access eye and cleaning port,
incl. connecting kit with water
meter for discharge control.

Installation in full flow return or flow
of an central heating.

Manufacturer: elector GmbH, Germany
Model: elector S10-V
Article-no.: 14020

Downloads

Download Datasheet elector S10Datasheet elector S10